A Simple Method to Assess Loadability of Radial Distribution Networks
2005
This paper proposes a simple method to asses loadability in radial distribution systems. The relevant problem of voltage stability has been dealt with in past times with reference to higher voltage systems for generation and transmission. In more recent papers, the problem has been considered also at distribution level, since the new electrical energy market requirements and the increasing loadings are now more and more influencing these systems. The proposed method is based on a static approach and proceeds by first evaluating the stability indices and then the different loadability factors (related to real, reactive and apparent power). These calculations are carried out by identifying, s…
Wind Turbine Mechanical Characteristics and Grid Parameters Influence on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of wind turbine mechanical characteristic of construction and grid parameters on the transient voltage stability of a fixed speed wind turbine (FSWT) connected to a simple grid. The model of FSWT has been developed in Matlab/Simulink. Using this model, a three-phase fault is applied close to the wind turbine (WT) and cleared by disconnecting the faulted line. The effects of mechanical construction of WT and of grid parameters on the voltage stability of this simple case are evaluated and discussed. The considered parameters are the inertia coefficient of the WT, the short-circuit power at the connection bus, the hub-generator resonant frequency, the wind spee…
Effects of Electrical Parameters of Induction Generator on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of electrical parameters of the induction generator on the transient voltage stability of a fixed speed wind turbine connected to a simple grid; the dynamic behavior of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed in the simulation tool Matlab/Simulink. Itpsilas composed by the induction generator, the shaft system, the aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phases fault is applied close to the wind turbine and cleared by disconnecting the faulted line. The effect of different electrical parameters of the induction generator on the vo…
Load modelling influence on voltage stability assessment in distribution systems. Part II: Extension to a complex radial system and applications
2006
The single-line equivalent model is commonly used for voltage stability studies in both distribution and transmission systems. Referring to a single-line system, in the companion paper [1] the authors presented the theoretical aspects of voltage stability related to the load characteristics. In particular, expressions of the stability index for constant power, constant impedance and constant current loads, singularly and in all the possible combinations have been obtained. This index indicates how far the load node is from its voltage collapse point, allowing the maximum load power beyond which voltage collapse takes place to be evaluated. In this paper a simple method to evaluate the param…
Load modelling influence on voltage stability assessment in distribution systems. Part I: Stability index and critical power for a single-line system
2006
The single-line equivalent model is commonly used for voltage stability studies in both distribution and transmission systems. Referring to a single-line system, in the companion paper [1] the authors presented the theoretical aspects of voltage stability related to the load characteristics. In particular, expressions of the stability index for constant power, constant impedance and constant current loads, singularly and in all the possible combinations have been obtained. This index indicates how far the load node is from its voltage collapse point, allowing the maximum load power beyond which voltage collapse takes place to be evaluated. In this paper a simple method to evaluate the param…
Voltage Collapse Proximity Assessment for Radial Distribution Networks
2005
The paper deals with voltage stability assessment in radial distribution networks. The voltage collapse proximity index already utilized in literature for power transmission systems is assumed. Based on the optimal impedance solution of a two-bus equivalent system, this index indicates how far the load nodes of the actual network are from their voltage collapse points, allowing the weak node and its maximum load power beyond which voltage collapse takes place to be identified. The proposed method differs from the other methods on the determination of the parameters which define the two-bus equivalent of the network, allowing to better identify the maximum loading point beyond which the volt…
Transient stability simulation of a fixed speed wind turbine by Matlab/Simulink
2007
This paper describes the dynamic behavior of a typical fixed speed wind turbine connected to the grid; the model is developed in the simulation tool Matlab/Simulink and created as a modular structure. The pitch control system is used for stabilization of the wind turbine at grid faults. In this way, voltage stability of the system with grid-connected wind turbines can be improved by using blade-angle control for a temporary reduction of the wind turbine power during a short-circuit fault in the grid. This paper shows a new variable control for maintaining of voltage stability, when a three-phase fault is applied close to the wind turbine and cleared by disconnecting the affected line. In th…